How it calculates

Model: Ibat=Iload Vload/(ηVbat)+Iq; Qusable=Qnom×retention factors; Peukert drain=Σ duty·Iref(I/Iref)^k; t=ln(1+λQ/Ieq)/λ.

Assumptions

  • Average battery voltage and regulator efficiency are fixed. Peukert exponent is mainly applicable to lead-acid and must come from battery measurements; k=1 gives ideal coulomb counting.
  • Duty-state Peukert drain is a screening approximation without recovery effects. Self-discharge is exponential in remaining usable charge; cutoff is represented by the usable-capacity factor.

Worked example

These are the calculator's default inputs. Change any input above to recalculate.

Inputs

Rated battery capacity
2 Ah
Average battery voltage
3.7 V
Regulated load voltage
3.3 V
Sleep current at load
0.00001 A
Active current at load
0.02 A
Transmit current at load
0.1 A
Active duty excluding TX
5 %
Transmit duty
1 %
Regulator efficiency
90 %
Regulator battery-side quiescent current
0.000002 A
Temperature capacity retention
90 %
Ageing capacity retention
90 %
Usable depth/cutoff capacity
80 %
Peukert exponent (1 disables)
1
Capacity rating discharge period
20 h
Self-discharge per 30 days
2 %

Results

Estimated runtime
644.319 h
Average load current
0.0020094 A
Average battery current
0.0019933 A
Derated usable capacity
1.296 Ah
Estimated runtime
26.8466 days
Rate-adjusted equivalent drain
0.0019933 A