SDG Electronics

Conducted EMI differential-mode estimate

Trapezoidal pulse harmonics, user-defined LISN transfer and a damped LC filter estimate.

Development preview. Check the assumptions below before relying on a result. Calculations run in your browser.

Loading calculator…

How it calculates

Assumptions

  • Pulse is an ideal rectangular waveform convolved with a finite ramp; harmonic amplitude uses sinc smoothing. Duty refers to pulse area, and results are discrete RMS Fourier lines.
  • LISN value is a user-supplied effective differential-mode transimpedance, not a universally valid 50 Ω conversion.
  • The filter is an ideal second-order voltage-transfer estimate with specified damping. Common mode, parasitics, spread spectrum, detector bandwidth, quasi-peak detection and test setup are absent.
  • The entered limit is a comparison target only. This calculator does not assert EMC compliance.

Worked example

These are the calculator's default inputs. Change any input above to recalculate.

Inputs

Pulse-current height
2 A
Pulse area duty
0.4
Switching frequency
200000 Hz
Symmetric ramp smoothing time
2e-8 s
Number of harmonics
50
Effective DM LISN transimpedance
25 Ω
User-selected comparison limit
60 dBµV
Differential filter series L
0.00001 H
Differential filter shunt C
0.000001 F
Effective filter damping resistance
1 Ω

Results

Largest filtered modeled harmonic
123.179 dBµV
Maximum additional attenuation required
63.1792 dB
Largest modeled harmonic
146.611 dBµV
Frequency of largest filtered harmonic
200000 Hz

All electronics calculators