SDG #05 Medical Isolation Transformer Teardown and Modifications
Medically rated isolation transformers turn up on the surplus market fairly often, and they can make an excellent bench safety upgrade for anyone probing live mains circuits. This look at the REO Inductive Components REO-MED 1000 explains why: medical grade units are built to tighter leakage current limits than industrial isolation transformers, which is exactly the characteristic you want when the goal is preventing a fault path through you to earth.
The catch with ex-medical equipment is the connectors. Units like this typically ship with hospital specific outlets or bare terminal blocks rather than anything convenient for a workshop, so the practical value of the teardown is seeing what is involved in retrofitting a normal UK twin 13A socket plus a pair of 4mm banana posts for direct probe or clip lead connection. That second addition is the genuinely useful one for electronics work, since it lets you feed an isolated supply into a device under test without a plug and flying lead adapter.
Along the way the internal construction is examined: the transformer core and winding arrangement, the earth bonding scheme, and how much room the enclosure leaves for extra hardware. There is also a worthwhile detour into crimping insulated ring terminals properly, which matters more than it sounds when the joint is carrying mains current inside a metal case.
Anyone considering a similar conversion should treat this as a guide to the thinking as much as the wiring: keep the earthing arrangement intact, respect the VA rating of the transformer, and make sure every added connection is mechanically sound before the lid goes back on.